Overview
For laboratories that want to perform both Solution and Semimicro Oxygen Bomb calorimetry tests, Parr offers the 6765 Combination Calorimeter. This includes the 6772 Calorimetric Thermometer module plus a calorimeter module and conversion parts for both the 6775 Solution Calorimeter and the 6725 Semimicro Calorimeter. This option has been popular with teaching laboratories that wish to include both types of experiments in their laboratory sessions.
Model Number
6765
Precision Classification
0.4% Class
Operator time Per test
6-10 minutes
Temperature Sensitivity
0.0001 °C
Energy Measurement Range
2 - 1000 Calories
Detection Limit
0.1 Calorie
Energy Equivalent
100 – 145 Calories/°C
Maximum Volume, Solute
20 mL
Required Volume, Solvent
90 – 120 mL
Balance Communication
USB Port
Printer Communication
USB Port
Network Connection
TCP/IP via Ethernet
Dimensions (cm)
6755: 22w x 33d x 33h 6772: 56w x 36d x 31h
Description
6765 Combination Calorimeter
For laboratories that want to perform both Solution and Semimicro Oxygen Bomb calorimetry tests, Parr offers the 6765 Combination Calorimeter. This includes the 6772 Calorimetric Thermometer module plus a calorimeter module and conversion parts for both the 6775 Solution Calorimeter and the 6725 Semimicro Calorimeter. This option has been popular with teaching laboratories that wish to include both types of experiments in their laboratory sessions.
Overview
6400 Automatic Isoperibol Oxygen Bomb Calorimeter

The 6400 Automatic Isoperibol Oxygen Bomb Calorimeter represents the next evolutionary step in the Parr automated calorimeters. Inclusive and compact, the instrument incorporates a closed loop cooling subsystem into the calorimeter.

This subsystem uses a thermoelectric cooler assembly attached directly to a one liter water tank which supplies cooling water to the calorimeter. An external nitrogen pressurized tank is used to supply rinse water to the calorimeter. This model features the fixed bomb and bucket design, allowing for automated bucket and jacket fill as well as automated vessel fill and rinse. The 6400 Oxygen Bomb Calorimeter requires one minute of operator time per test, allowing a technician to operate up to four calorimeters simultaneously.

6400 Automatic Isoperibol Oxygen Bomb Calorimeter

6400 Automatic Isoperibol Oxygen Bomb Calorimeter

The 6400 Automatic Isoperibol Oxygen Bomb Calorimeter represents the next evolutionary step in the Parr automated calorimeters. Inclusive and compact, the instrument incorporates a closed loop cooling subsystem into the calorimeter.

This subsystem uses a thermoelectric cooler assembly attached directly to a one liter water tank which supplies cooling water to the calorimeter. An external nitrogen pressurized tank is used to supply rinse water to the calorimeter. This model features the fixed bomb and bucket design, allowing for automated bucket and jacket fill as well as automated vessel fill and rinse. The 6400 Oxygen Bomb Calorimeter requires one minute of operator time per test, allowing a technician to operate up to four calorimeters simultaneously.

Model Number
6400
Tests Per Hour
6 – 7
Operator Time Per Test
1 Minute
Temperature resolution
0.0001 ℃
Precision Classification
0.1% Class
Jacket Type
Isoperibol, Water Jacket
Oxygen Fill
Automatic
Bucket Fill
Automatic
Bomb Wash
Automatic
Memory
1000 tests
Bomb Model Options
1138, 250mL, Alloy 20
1138CL, 250mL, Alloy G30
Balance Communication
USB Port
Printer Communication
USB Port
Network Connection
TCP/IP via Ethernet
Dimensions (cm)
42w x 46d x 51h