ECS 4010 CHNS/O Analyzer

nc Technologies
Overview

The ECS 4010 is a fully automatic elemental analyzer for organic elemental analysis using high-temperature catalytic combustion (Dumas method). It enables simultaneous determination of CHNS and optional O, with modes for N, CN, CHN, and CHNS analysis.

Designed for high-throughput laboratories, it combines speed, precision, and automation. A dual-oven configuration reduces catalyst consumption while ensuring consistent results across diverse applications in pharmaceuticals, petrochemicals, and marine biology.

Its flexible setup supports multiple autosamplers and reactors, with a self-calibrating TCD detector that requires no reference gas. Robust and reliable, the ECS 4010 also connects seamlessly to isotope ratio determination units.

ANALYTICAL RANGE CUp to 12 mg
ANALYTICAL RANGE HUp to 2 mg
ANALYTICAL RANGE NUp to 10 mg
ANALYTICAL RANGE SUp to 3 mg
ANALYTICAL RANGE OUp to 2 mg
SAMPLE SIZEUp to 200 mg (depending on C content)
PRECISION≤ 0.2% RSD
COMBUSTION VIEWING FACILITYStandard top viewing
DETECTION LIMIT200 PPM
REACTOR OXIDATION800–1100 °C
REACTOR REDUCTION600–1100 °C
ANALYSIS TIME10 minutes for CHNS, 5 minutes for O with standard GC column
CALIBRATIONSLinear, quadratic, cubic
GAS UTILITIESCompressed air (dry and oil-free), Helium (He), Oxygen (O₂). O₂ 99.999% (5.0) purity, 3–5 bar. He 99.999% (5.0) purity, 3–5 bar.
Description
ECS 4010 CHNS/O Analyzer
  • The ECS 4010 is an automatic elemental analyzer that represents an evolution of elemental analysis techniques based on flash combustion and chromatographic separation. The combustion gases CO₂, H₂O, SO₂, and N₂ are separated in a GC column maintained at a constant temperature, selectable by the user between 30°C and 110°C. The detection and determination of the concentrations of the various elements are performed using a thermal conductivity detector (TCD).
  • The ECS 4010 is a fully automated analytical unit controlled by a microprocessor and interfaced with a computer. Results can be displayed directly on a PC using dedicated software.
  • Manual gas settings
  • High sensitivity, accuracy, and precision
  • Flexibility and versatility of application
  • Detector does not require reference gas
  • Powerful software for viewing results on a computer
  • Two types of samplers available: pneumatic and Zero Blank (ZB)
  • Easy connection to mass spectrometers and other detectors for stable isotope analysis
  • Low operating and management costs
  • Low initial instrument investment
  • Standby mode to save gas, energy, and time